60 HzTier 4 FinalMobile
350 kVA Triton Rental Grade Generator TP-RS350-T4F-RENTAL Tier 4 Rental
TP-RS350-T4F-RENTAL
Engine Scania DC13 084A
- Standby
- 308 kW / 385 kVA
- Prime
- 280 kW / 350 kVA
Diesel · 60 Hz · Enclosed or open
Commercial & Industrial Power Equipment Worldwide
Each of the 8 sets in this range of 301-500 kW Tier 4 Final generators is a mobile diesel unit with 60 Hz output, and all share the same description: "Tier 4 Final emissions configuration."
Filter by power, engine, frequency, market eligibility and configuration to find the right unit.
60 HzTier 4 FinalMobile
TP-RS350-T4F-RENTAL
Engine Scania DC13 084A
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-S350-T4F
Engine Scania DC13 085A
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RS400-T4F-RENTAL
Engine Scania DC13 085A
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-S440-T4F
Engine Scania DC16 084A
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RS500-T4F-RENTAL
Engine Scania DC16 084A
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-JD440-T4F
Engine John Deere 6136CG550
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-JD500-T4F
Engine John Deere 6136CG550
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RJD500-T4F-RENTAL
Engine John Deere 6136CG550
Diesel · 60 Hz · Enclosed or open
Showing 8 of 8
No products match these filters.
Many units can be configured to the specification you need. Ask about a custom configuration or .
Five questions that decide which unit fits. Each unit's page has its full published specifications.
A standby rating is for backup duty: the generator starts when utility power fails and carries the load until the grid comes back. A prime rating is for sites where the generator is the main source of power, running for long periods while the load rises and falls.
All 8 units here publish both ratings; on each of them the standby rating is the higher figure.
Generators are rated in kVA and kW. kVA = kW ÷ power factor, and generator ratings typically use a power factor of 0.8. A few units are published with other ratios, so always use the unit's own kW and kVA figures. International ratings are often quoted in kVA: switch this list between kW and kVA in the toolbar.
Generator frequency has to match the local grid and the equipment on it. Grids in North America run mainly at 60 Hz, while Europe and much of Asia and Africa run at 50 Hz. Set the project destination above to see its grid frequency.
Of the 8 units here, 8 at 60 Hz.
Each unit's page lists the configurations it is offered in (enclosed, open), with dimensions and weights where published. 8 of the 8 units here are offered in more than one configuration. 8 are mobile units.
EPA generatorsTier 4 Final generatorsExport generatorsDo you need a Tier 4 generator?
Each of the 8 sets in this range of 301-500 kW Tier 4 Final generators is a mobile diesel unit with 60 Hz output, and all share the same description: "Tier 4 Final emissions configuration."
The kW figures quoted here are standby ratings, which describe output for backup use while utility power is down. If a set will instead serve as the main source of power for long stretches under a changing load, size it on its prime rating, which is lower than the standby rating of the same unit. Our team can help confirm the right unit; send your requirements through the quote form.
Tell us your required power, destination and application. Our team can help identify the right generator.