60 HzTier 4 FinalMobile
1100 kW Triton Diesel Generator TP-V1100-T4F-Twin Pack
TP-V1100-T4F-Twin Pack
Engine Volvo TWD1672GE
- Standby
- 1,100 kW / 1,376 kVA
- Prime
- 1,000 kW / 1,250 kVA
Diesel · 60 Hz · Enclosed or open
Commercial & Industrial Power Equipment Worldwide
The 1001 kW and up EPA Generators group is aimed at US sites: all 14 Triton diesel units run at 60 Hz, and the market labels split into 10 USA EPA-certified sets and 4 Tier 4 Final sets. Standby ratings range from 1100 kW to 3300 kW.
Filter by power, engine, frequency, market eligibility and configuration to find the right unit.
60 HzTier 4 FinalMobile
TP-V1100-T4F-Twin Pack
Engine Volvo TWD1672GE
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RV1250-T4F-RENTAL TWIN PACK
Engine Volvo TWD1672GE
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RV1425-T4F-RENTAL TWIN PACK
Engine Volvo TWD1673GE
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-V1250-T4F-Twin Pack
Engine Volvo TWD1673GE
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-B1300-T2-60-UL
Engine Baudoin 12M33G12D2/6
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-C1500-T2-60
Engine Cummins QSK50-G4
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-B1500-T2-60-UL
Engine Baudoin 16M33G12D2/6
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-B1750-T2-60-UL
Engine Baudouin 16M33G4D2/6
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-C2000-T2-60
Engine Cummins QSK60-G6
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-B2000-T2-60-UL
Engine Baudoin 20M33G4D2/6
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-C2250-T2-60
Engine Cummins QSK60-G14
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-B2500-T2-60-UL
Engine Baudoin 12M55G5D2/6
Diesel · 60 Hz · Enclosed or open
Not sure which generator you need?
Tell us what you're powering, the destination country, the estimated load and whether it is standby or prime, and our team can help recommend a suitable generator.
60 HzUSA EPA
TP-B3000-T2-60-UL
Engine Baudoin 16M55G6D2/6
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-B3300-T2-60-UL
Engine Baudoin 16M55G8D2/6
Diesel · 60 Hz · Enclosed or open
Showing 14 of 14
No products match these filters.
Many units can be configured to the specification you need. Ask about a custom configuration or .
Five questions that decide which unit fits. Each unit's page has its full published specifications.
A standby rating is for backup duty: the generator starts when utility power fails and carries the load until the grid comes back. A prime rating is for sites where the generator is the main source of power, running for long periods while the load rises and falls.
All 14 units here publish both ratings; on each of them the standby rating is the higher figure.
Generators are rated in kVA and kW. kVA = kW ÷ power factor, and generator ratings typically use a power factor of 0.8. A few units are published with other ratios, so always use the unit's own kW and kVA figures. International ratings are often quoted in kVA: switch this list between kW and kVA in the toolbar.
Generator frequency has to match the local grid and the equipment on it. Grids in North America run mainly at 60 Hz, while Europe and much of Asia and Africa run at 50 Hz. Set the project destination above to see its grid frequency.
Of the 14 units here, 14 at 60 Hz.
Each unit's page lists the configurations it is offered in (enclosed, open), with dimensions and weights where published. 14 of the 14 units here are offered in more than one configuration. 4 are mobile units.
EPA generatorsTier 4 Final generatorsExport generatorsDo you need a Tier 4 generator?
The 1001 kW and up EPA Generators group is aimed at US sites: all 14 Triton diesel units run at 60 Hz, and the market labels split into 10 USA EPA-certified sets and 4 Tier 4 Final sets. Standby ratings range from 1100 kW to 3300 kW.
Baudouin engines appear in 7 of the 14, Volvo engines in 4 and Cummins engines in 3. Each unit is listed in an enclosed and an open configuration, and 4 are mobile units. The Tier 4 Final units are also grouped on a separate page for this size band.
Electrical drawings for large buildings sometimes give loads in kVA rather than kW. To convert, divide kW by the power factor; generator ratings are normally quoted at 0.8, so a set's kVA value is higher than its kW value. The kW to kVA converter handles the math. Send your requirements through the quote form, including the site load.
Tell us your required power, destination and application. Our team can help identify the right generator.