60 HzUSA EPA
10 kW Triton Diesel Generator TP-P10-T4i EPA Certified
TP-10-T4i
Engine Perkins 403D-11G
- Standby
- 10 kW / 12.4 kVA
- Prime
- 9 kW / 11.2 kVA
Diesel · 60 Hz · Enclosed or open
Commercial & Industrial Power Equipment Worldwide
Every unit on this page is a 60 Hz Triton generator meant for US sites, matching the frequency used across most of North America. The 0-100 kW EPA Generators listed here number 28, rated from 10 kW to 100 kW standby.
Filter by power, engine, frequency, market eligibility and configuration to find the right unit.
60 HzUSA EPA
TP-10-T4i
Engine Perkins 403D-11G
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-K15-T4F
Engine Kubota V1505-E4BG1
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RK15-T4F-RENTAL
Engine Kubota V1505-E4BG1
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-P15-T4i
Engine Perkins 403D-15G
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-P20-T4i
Engine Perkins 404D-22G
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-P20-T4i-UL
Engine Perkins 404D-22G
Diesel · 60 Hz · Enclosed or open skid
60 HzTier 4 FinalMobile
TP-K25-T4F
Engine Kubota D1803-CR-TIE4BG
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RK25-T4F-RENTAL
Engine Kubota D1803-CR-TIE4BG
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-P29-T4i
Engine Perkins 404D-22TG
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-P30-T4i-UL
Engine Perkins 404D-22TG
Diesel · 60 Hz · Enclosed or open skid
60 HzTier 4 FinalMobile
TP-K30-T4F
Engine Kubota V2403-CR-TIE4BG
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RK35-T4F-RENTAL
Engine Kubota V2403-CR-TIE4BG
Diesel · 60 Hz · Enclosed or open
Not sure which generator you need?
Tell us what you're powering, the destination country, the estimated load and whether it is standby or prime, and our team can help recommend a suitable generator.
60 HzUSA EPA
TP-Y30-T4i-SGUL
Engine Yanmar 4TNV98T
Diesel · 60 Hz · Enclosed
60 HzUSA EPA
TP-Y40-T4i-SGUL
Engine Yanmar 4TNV98T
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-NG40-S-K-UL
Engine PSI Engine 4.3L
Natural gas / LP · 60 Hz
60 HzTier 4 FinalMobile
TP-JD50-T4F
Engine John Deere 3029HG530
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RJD55-T4F-RENTAL
Engine John Deere 3029HG530
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-P55-T3
Engine Perkins 1104D-44TG1
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-P55-T3-UL
Engine Perkins 1104D-44TG1
Diesel · 60 Hz · Enclosed or open skid
60 HzUSA EPA
TP-P65-T3-UL
Engine Perkins 1104D-E44TG1
Diesel · 60 Hz · Enclosed or open skid
60 HzUSA EPA
TP-NG80-S-K-UL
Engine PSI Engine 5.7LT
Natural gas / LP · 60 Hz
60 HzUSA EPA
TP-P80-T3
Engine Perkins 1104D-E44TAG1
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-P80-T3-UL
Engine Perkins 1104D-E44TAG1
Diesel · 60 Hz · Enclosed or open skid
60 HzTier 4 FinalMobile
TP-JD88-T4F
Engine John Deere 4045HFG04
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RJD100-T4F-RENTAL
Engine John Deere 4045HFG04
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-NG100-S-K-UL
Engine PSI Engine 5.7LT CAC
Natural gas / LP · 60 Hz
60 HzUSA EPA
TP-P100-T3
Engine Perkins 1104D-E44TAG2
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-P100-T3-UL
Engine Perkins 1104D-E44TAG2
Diesel · 60 Hz · Enclosed or open skid
Showing 24 of 28
No products match these filters.
Many units can be configured to the specification you need. Ask about a custom configuration or .
Five questions that decide which unit fits. Each unit's page has its full published specifications.
A standby rating is for backup duty: the generator starts when utility power fails and carries the load until the grid comes back. A prime rating is for sites where the generator is the main source of power, running for long periods while the load rises and falls.
26 of the 28 units here publish both ratings; on each of them the standby rating is the higher figure.
Generators are rated in kVA and kW. kVA = kW ÷ power factor, and generator ratings typically use a power factor of 0.8. A few units are published with other ratios, so always use the unit's own kW and kVA figures. International ratings are often quoted in kVA: switch this list between kW and kVA in the toolbar.
Generator frequency has to match the local grid and the equipment on it. Grids in North America run mainly at 60 Hz, while Europe and much of Asia and Africa run at 50 Hz. Set the project destination above to see its grid frequency.
Of the 28 units here, 28 at 60 Hz.
Each unit's page lists the configurations it is offered in (enclosed, open, open skid), with dimensions and weights where published. 24 of the 28 units here are offered in more than one configuration. 10 are mobile units.
EPA generatorsTier 4 Final generatorsExport generatorsDo you need a Tier 4 generator?
Every unit on this page is a 60 Hz Triton generator meant for US sites, matching the frequency used across most of North America. The 0-100 kW EPA Generators listed here number 28, rated from 10 kW to 100 kW standby. By market label, 18 are USA EPA-certified and 10 are Tier 4 Final.
Fuel and engine make are the main ways to split the group. Diesel accounts for 25 units, and 3 run on natural gas or LP; gas units of this size are also grouped under 0-100 kW natural gas generators. Engines come from Perkins (13), Kubota (6), John Deere (4), PSI / GM (3) and Yanmar (2). On the layout side, an enclosure is listed for 25, an open set for 18 and an open skid for 6, while 10 are mobile units.
When you compare figures, remember that the kW figures above are standby ratings, meant for backup during a utility outage. If the set will run as the main power source for long stretches under a varying load, its prime rating applies, and that figure is lower. Our team can help confirm the right unit.
Tell us your required power, destination and application. Our team can help identify the right generator.