USA EPA-certified on 10 units and Tier 4 Final on 9: those market labels split the 101-300 kW EPA Generators, a group of 19 Triton sets for US sites, all at 60 Hz and rated from 110 kW to 308 kW standby. Of these, 9 are mobile units.

Filter by power, engine, frequency, market eligibility and configuration to find the right unit.

Power
Market
Engine
Configuration
Type
Duty
Fuel

19 of 19 generators

Generators

Buyer's guide

Choosing a 101–300 kW generator

Five questions that decide which unit fits. Each unit's page has its full published specifications.

Standby or prime?

A standby rating is for backup duty: the generator starts when utility power fails and carries the load until the grid comes back. A prime rating is for sites where the generator is the main source of power, running for long periods while the load rises and falls.

18 of the 19 units here publish both ratings; on each of them the standby rating is the higher figure.

kW or kVA?

Generators are rated in kVA and kW. kVA = kW ÷ power factor, and generator ratings typically use a power factor of 0.8. A few units are published with other ratios, so always use the unit's own kW and kVA figures. International ratings are often quoted in kVA: switch this list between kW and kVA in the toolbar.

50 Hz or 60 Hz?

Generator frequency has to match the local grid and the equipment on it. Grids in North America run mainly at 60 Hz, while Europe and much of Asia and Africa run at 50 Hz. Set the project destination above to see its grid frequency.

Of the 19 units here, 19 at 60 Hz.

Open or enclosed?

Each unit's page lists the configurations it is offered in (enclosed, open, open skid), with dimensions and weights where published. 18 of the 19 units here are offered in more than one configuration. 9 are mobile units.

USA EPA, Tier 4 Final or international?
  • USA EPA (10 here): EPA-certified configuration for the US market.
  • Tier 4 Final (9 here): Tier 4 Final emissions configuration.

About 101-300 kW EPA Generators

USA EPA-certified on 10 units and Tier 4 Final on 9: those market labels split the 101-300 kW EPA Generators, a group of 19 Triton sets for US sites, all at 60 Hz and rated from 110 kW to 308 kW standby. Of these, 9 are mobile units.

John Deere supplies the engine in 8 of them, Perkins in 6 and Cummins in 3, with 1 Scania and 1 PSI / GM. Diesel covers 18 units, and 1 runs on natural gas or LP; that gas set also has its own listing under 101-300 kW natural gas generators.

Layout is the other main choice. Enclosed versions are listed for 18 units, open sets for 14 and open skids for 4. An open set or skid is intended for an engine room or other sheltered space, whereas an enclosure shields the generator from weather and lowers its noise for outdoor placement. If you need the Tier 4 Final units only, see 101-300 kW Tier 4 Final generators. If you are unsure whether a site calls for an open or enclosed layout, our team can help confirm the right unit.

Can't find the right configuration?

Tell us your required power, destination and application. Our team can help identify the right generator.

Compare generators

Values as published for each unit. Full specifications, documents and any market restriction are on each product page.