60 HzTier 4 FinalMobile
550 kW Triton Diesel Generator TP-V550-T4F Tier 4 Final
TP-V550-T4F
Engine Volvo TWD1672GE
- Standby
- 550 kW / 688 kVA
- Prime
- 500 kW / 625 kVA
Diesel · 60 Hz · Enclosed or open
Commercial & Industrial Power Equipment Worldwide
Every unit among these 501-1000 kW EPA generators lists both an open and an enclosed configuration.
Filter by power, engine, frequency, market eligibility and configuration to find the right unit.
60 HzTier 4 FinalMobile
TP-V550-T4F
Engine Volvo TWD1672GE
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RV625-T4F-RENTAL
Engine Volvo TWD1672GE
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-P550-T2
Engine Perkins 2506C-E15TAG4
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-P600-T2
Engine Perkins 2806C-E18TAG3
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-P600-T2-UL
Engine Perkins 2806C-E18TAG3
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RS700-T4F-Twin Pack
Engine Scania DC13 084A
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-V625-T4F
Engine Volvo TWD1673GE
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RV713-T4F-RENTAL
Engine Volvo TWD1673GE
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-S700-T4F-Twin Pack
Engine Scania DC13 085A
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-P750-T2-UL
Engine Perkins 2806C-E18TTAG7
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-C800-T2-60
Engine Cummins QSK23-G7
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-S880-T4F-Twin Pack
Engine Scania DC16 084A
Diesel · 60 Hz · Enclosed or open
Not sure which generator you need?
Tell us what you're powering, the destination country, the estimated load and whether it is standby or prime, and our team can help recommend a suitable generator.
60 HzTier 4 FinalMobile
TP-RS1000-T4F-Twin Pack
Engine Scania DC16 084A
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-C1000-T2-60
Engine Cummins QST30-G5
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-P1000-T2-S-UL
Engine Perkins 5008C-E30TAG5
Diesel · 60 Hz · Enclosed or open
Showing 15 of 15
No products match these filters.
Many units can be configured to the specification you need. Ask about a custom configuration or .
Five questions that decide which unit fits. Each unit's page has its full published specifications.
A standby rating is for backup duty: the generator starts when utility power fails and carries the load until the grid comes back. A prime rating is for sites where the generator is the main source of power, running for long periods while the load rises and falls.
All 15 units here publish both ratings; on each of them the standby rating is the higher figure.
Generators are rated in kVA and kW. kVA = kW ÷ power factor, and generator ratings typically use a power factor of 0.8. A few units are published with other ratios, so always use the unit's own kW and kVA figures. International ratings are often quoted in kVA: switch this list between kW and kVA in the toolbar.
Generator frequency has to match the local grid and the equipment on it. Grids in North America run mainly at 60 Hz, while Europe and much of Asia and Africa run at 50 Hz. Set the project destination above to see its grid frequency.
Of the 15 units here, 15 at 60 Hz.
Each unit's page lists the configurations it is offered in (enclosed, open), with dimensions and weights where published. 15 of the 15 units here are offered in more than one configuration. 8 are mobile units.
EPA generatorsTier 4 Final generatorsExport generatorsDo you need a Tier 4 generator?
Every unit among these 501-1000 kW EPA generators lists both an open and an enclosed configuration. An open set suits a dedicated generator room that already shelters it, while an enclosure adds weather and sound protection when the set stands outdoors. The 15 diesel units here have standby ratings from 550 kW to 1,000 kW, and all produce 60 Hz power.
Tier 4 Final covers 8 units: "Tier 4 Final emissions configuration." The USA EPA-certified label covers the remaining 7: "EPA-certified configuration for the US market." Engines come from Perkins (5 units), Volvo (4), Scania (4) and Cummins (2), and 8 of the 15 are mobile.
Our team can help confirm the right unit for your site; to start, send your requirements through the quote form. For more Tier 4 Final options, see Tier 4 generators.
Tell us your required power, destination and application. Our team can help identify the right generator.