Commercial & Industrial Power Equipment Worldwide

Equipment for use in

Commercial Generators

The commercial generators listed here number 185, with standby ratings that begin at 8 kW and reach 3,300 kW. Most run on diesel (181), and 4 are natural gas or LP sets.

Filter by power, engine, frequency, market eligibility and configuration to find the right unit.

Power
Frequency
Market
Engine
Configuration
Type
Duty
Fuel

Units marked International are built for markets outside the United States and Canada. Set where it will be used for frequency and market suggestions, or use the Market filter to see only the units for your destination.

185 of 185 generators

Generators

Showing 24 of 185

Buyer's guide

Choosing the right generator

Five questions that decide which unit fits. Each unit's page has its full published specifications.

Standby or prime?

A standby rating is for backup duty: the generator starts when utility power fails and carries the load until the grid comes back. A prime rating is for sites where the generator is the main source of power, running for long periods while the load rises and falls.

182 of the 185 units here publish both ratings; on each of them the standby rating is the higher figure.

kW or kVA?

Generators are rated in kVA and kW. kVA = kW ÷ power factor, and generator ratings typically use a power factor of 0.8. A few units are published with other ratios, so always use the unit's own kW and kVA figures. International ratings are often quoted in kVA: switch this list between kW and kVA in the toolbar.

50 Hz or 60 Hz?

Generator frequency has to match the local grid and the equipment on it. Grids in North America run mainly at 60 Hz, while Europe and much of Asia and Africa run at 50 Hz. Set the project destination above to see its grid frequency.

Of the 185 units here, 40 at 50 Hz and 145 at 60 Hz.

Open or enclosed?

Each unit's page lists the configurations it is offered in (enclosed, open, open skid), with dimensions and weights where published. 180 of the 185 units here are offered in more than one configuration. 44 are mobile units.

USA EPA, Tier 4 Final or international?
  • USA EPA (56 here): EPA-certified configuration for the US market.
  • Tier 4 Final (39 here): Tier 4 Final emissions configuration.
  • International (84 here): Configured for international markets (non-EPA).

Units marked International are built for markets outside the United States and Canada. Each of their product pages carries the published US/Canada restriction.

About Commercial Generators

The commercial generators listed here number 185, with standby ratings that begin at 8 kW and reach 3,300 kW. Most run on diesel (181), and 4 are natural gas or LP sets. Engines come from Perkins, Cummins, John Deere, Doosan, Scania, Volvo, Baudouin, Kubota, Yanmar and PSI / GM.

Narrowing the list

  • Market: 56 units are labeled USA EPA-certified, 39 Tier 4 Final and 84 International; for 6, eligibility is being confirmed.
  • Frequency: 145 units at 60 Hz and 40 at 50 Hz. Choose the frequency that matches the site's grid and equipment.
  • Configuration: 181 units have an enclosed option, 167 an open set and 13 an open skid.
  • Mobility: 44 are mobile units.

Ratings are quoted as standby figures. If your load list is in kVA, note that generator ratings usually assume a 0.8 power factor, and kVA equals kW divided by that factor. Our team can help confirm the right unit when you send your requirements through the quote form.

Can't find the right configuration?

Tell us your required power, destination and application. Our team can help identify the right generator.

Compare generators

Values as published for each unit. Full specifications, documents and any market restriction are on each product page.