UL2200 Listed EPA Generators

UL2200 Listed EPA Generators on this page all carry the USA EPA-certified label: 29 Triton units, each producing 60 Hz, the grid frequency used across most of North America.

Filter by power, engine, frequency, market eligibility and configuration to find the right unit.

Power
Engine
Configuration
Duty
Fuel

29 of 29 generators

Generators

Showing 24 of 29

Buyer's guide

Choosing the right generator

Five questions that decide which unit fits. Each unit's page has its full published specifications.

Standby or prime?

A standby rating is for backup duty: the generator starts when utility power fails and carries the load until the grid comes back. A prime rating is for sites where the generator is the main source of power, running for long periods while the load rises and falls.

26 of the 29 units here publish both ratings; on each of them the standby rating is the higher figure.

kW or kVA?

Generators are rated in kVA and kW. kVA = kW ÷ power factor, and generator ratings typically use a power factor of 0.8. A few units are published with other ratios, so always use the unit's own kW and kVA figures. International ratings are often quoted in kVA: switch this list between kW and kVA in the toolbar.

50 Hz or 60 Hz?

Generator frequency has to match the local grid and the equipment on it. Grids in North America run mainly at 60 Hz, while Europe and much of Asia and Africa run at 50 Hz. Set the project destination above to see its grid frequency.

Of the 29 units here, 29 at 60 Hz.

Open or enclosed?

Each unit's page lists the configurations it is offered in (enclosed, open skid, open), with dimensions and weights where published. 24 of the 29 units here are offered in more than one configuration.

USA EPA, Tier 4 Final or international?
  • USA EPA (29 here): EPA-certified configuration for the US market.

About UL2200 Listed EPA Generators

UL2200 Listed EPA Generators on this page all carry the USA EPA-certified label: 29 Triton units, each producing 60 Hz, the grid frequency used across most of North America.

  • Market: EPA-certified configuration for the US market.
  • Engines: Perkins on 16 units, Baudouin on 7, PSI / GM on 4 and Yanmar on 2.
  • Fuel: diesel on 25 units, natural gas or LP on 4.
  • Housing: enclosed versions are listed for 25 units, with open and open-skid versions also listed.

Standby ratings start at 20 kW and reach 3,300 kW. Those figures are quoted for backup duty, and generator ratings are usually stated at a 0.8 power factor, so the matching kVA value is the kW figure divided by 0.8. The kW to kVA calculator does this for any unit on the page. Send your requirements through the quote form.

Can't find the right configuration?

Tell us your required power, destination and application. Our team can help identify the right generator.

Compare generators

Values as published for each unit. Full specifications, documents and any market restriction are on each product page.