Prime EPA Generators are aimed at US sites where the generator carries the load day to day instead of waiting for an outage. All 92 Triton units here produce 60 Hz and fall into the US-market groups below.

Filter by power, engine, frequency, market eligibility and configuration to find the right unit.

Power
Market
Engine
Configuration
Type
Fuel

92 of 92 generators

Generators

Showing 24 of 92

Buyer's guide

Choosing the right generator

Five questions that decide which unit fits. Each unit's page has its full published specifications.

Standby or prime?

A standby rating is for backup duty: the generator starts when utility power fails and carries the load until the grid comes back. A prime rating is for sites where the generator is the main source of power, running for long periods while the load rises and falls.

All 92 units here publish both ratings; on each of them the standby rating is the higher figure.

kW or kVA?

Generators are rated in kVA and kW. kVA = kW ÷ power factor, and generator ratings typically use a power factor of 0.8. A few units are published with other ratios, so always use the unit's own kW and kVA figures. International ratings are often quoted in kVA: switch this list between kW and kVA in the toolbar.

50 Hz or 60 Hz?

Generator frequency has to match the local grid and the equipment on it. Grids in North America run mainly at 60 Hz, while Europe and much of Asia and Africa run at 50 Hz. Set the project destination above to see its grid frequency.

Of the 92 units here, 92 at 60 Hz.

Open or enclosed?

Each unit's page lists the configurations it is offered in (enclosed, open, open skid), with dimensions and weights where published. 90 of the 92 units here are offered in more than one configuration. 43 are mobile units.

USA EPA, Tier 4 Final or international?
  • USA EPA (53 here): EPA-certified configuration for the US market.
  • Tier 4 Final (39 here): Tier 4 Final emissions configuration.

About Prime EPA Generators

Prime EPA Generators are aimed at US sites where the generator carries the load day to day instead of waiting for an outage. All 92 Triton units here produce 60 Hz and fall into the US-market groups below.

  • USA EPA-certified (53 units): EPA-certified configuration for the US market.
  • Tier 4 Final (39 units): Tier 4 Final emissions configuration.
  • Fuel: diesel on 91 units, natural gas or LP on 1.

The kW values shown are standby ratings, from 10 kW to 3,300 kW. Prime duty means running as the primary source for extended hours while the load rises and falls, and the prime rating that applies is lower than the listed standby number, so size the set against the prime figure. Engines come from Perkins (31), John Deere (15), Cummins (12), Scania (10), Volvo (8), Baudouin (7), Kubota (6), Yanmar (2) and PSI / GM (1), and 43 are mobile units.

For a site outside the US, look at prime commercial generators, which also include International units. Otherwise, send your requirements through the quote form.