Prime Commercial Generators

Prime Commercial Generators are chosen when a set will be the main power source rather than a backup, often for long periods under a load that keeps changing.

Filter by power, engine, frequency, market eligibility and configuration to find the right unit.

Power
Frequency
Market
Engine
Configuration
Type
Fuel

Units marked International are built for markets outside the United States and Canada. Set where it will be used for frequency and market suggestions, or use the Market filter to see only the units for your destination.

182 of 182 generators

Generators

Showing 24 of 182

Buyer's guide

Choosing the right generator

Five questions that decide which unit fits. Each unit's page has its full published specifications.

Standby or prime?

A standby rating is for backup duty: the generator starts when utility power fails and carries the load until the grid comes back. A prime rating is for sites where the generator is the main source of power, running for long periods while the load rises and falls.

All 182 units here publish both ratings; on each of them the standby rating is the higher figure.

kW or kVA?

Generators are rated in kVA and kW. kVA = kW ÷ power factor, and generator ratings typically use a power factor of 0.8. A few units are published with other ratios, so always use the unit's own kW and kVA figures. International ratings are often quoted in kVA: switch this list between kW and kVA in the toolbar.

50 Hz or 60 Hz?

Generator frequency has to match the local grid and the equipment on it. Grids in North America run mainly at 60 Hz, while Europe and much of Asia and Africa run at 50 Hz. Set the project destination above to see its grid frequency.

Of the 182 units here, 40 at 50 Hz and 142 at 60 Hz.

Open or enclosed?

Each unit's page lists the configurations it is offered in (enclosed, open, open skid), with dimensions and weights where published. 180 of the 182 units here are offered in more than one configuration. 44 are mobile units.

USA EPA, Tier 4 Final or international?
  • USA EPA (53 here): EPA-certified configuration for the US market.
  • Tier 4 Final (39 here): Tier 4 Final emissions configuration.
  • International (84 here): Configured for international markets (non-EPA).

Units marked International are built for markets outside the United States and Canada. Each of their product pages carries the published US/Canada restriction.

About Prime Commercial Generators

Prime Commercial Generators are chosen when a set will be the main power source rather than a backup, often for long periods under a load that keeps changing. The 182 Triton units on this page are listed with their standby ratings, which run from 8 kW to 3,300 kW. For continuous duty the relevant number is the prime rating, which is lower than the standby figure for the same unit.

What the list covers

  • Engines: Perkins (94), Cummins (22), John Deere (15), Doosan (14), Scania (10), Volvo (8), Baudouin (7), Kubota (6), Yanmar (5) and PSI / GM (1).
  • Frequency: 142 units at 60 Hz and 40 at 50 Hz.
  • Market: 84 International, 53 USA EPA-certified, 39 Tier 4 Final and 6 with eligibility being confirmed.
  • Fuel: 181 diesel and 1 natural gas or LP; 44 are mobile units.