Commercial & Industrial Power Equipment Worldwide

Equipment for use in

Generators

This page lists every generator set on the site: 185 Triton units with standby ratings from 8 to 3300 kW. Nearly all of them run on diesel (181), and 4 use natural gas or LP. Of the 185, 44 are mobile.

Filter by power, engine, frequency, market eligibility and configuration to find the right unit.

Power
Frequency
Market
Engine
Configuration
Type
Duty
Fuel

Units marked International are built for markets outside the United States and Canada. Set where it will be used for frequency and market suggestions, or use the Market filter to see only the units for your destination.

185 of 185 generators

Generators

Showing 24 of 185

Buyer's guide

Choosing the right generator

Five questions that decide which unit fits. Each unit's page has its full published specifications.

Standby or prime?

A standby rating is for backup duty: the generator starts when utility power fails and carries the load until the grid comes back. A prime rating is for sites where the generator is the main source of power, running for long periods while the load rises and falls.

182 of the 185 units here publish both ratings; on each of them the standby rating is the higher figure.

kW or kVA?

Generators are rated in kVA and kW. kVA = kW ÷ power factor, and generator ratings typically use a power factor of 0.8. A few units are published with other ratios, so always use the unit's own kW and kVA figures. International ratings are often quoted in kVA: switch this list between kW and kVA in the toolbar.

50 Hz or 60 Hz?

Generator frequency has to match the local grid and the equipment on it. Grids in North America run mainly at 60 Hz, while Europe and much of Asia and Africa run at 50 Hz. Set the project destination above to see its grid frequency.

Of the 185 units here, 40 at 50 Hz and 145 at 60 Hz.

Open or enclosed?

Each unit's page lists the configurations it is offered in (enclosed, open, open skid), with dimensions and weights where published. 180 of the 185 units here are offered in more than one configuration. 44 are mobile units.

USA EPA, Tier 4 Final or international?
  • USA EPA (56 here): EPA-certified configuration for the US market.
  • Tier 4 Final (39 here): Tier 4 Final emissions configuration.
  • International (84 here): Configured for international markets (non-EPA).

Units marked International are built for markets outside the United States and Canada. Each of their product pages carries the published US/Canada restriction.

About Generators

This page lists every generator set on the site: 185 Triton units with standby ratings from 8 to 3300 kW. Nearly all of them run on diesel (181), and 4 use natural gas or LP. Of the 185, 44 are mobile.

Start with the market

  • USA EPA-certified: 56 units
  • Tier 4 Final: 39 units
  • International: 84 units
  • Eligibility being confirmed: 6 units

Units marked International are built for markets outside the United States and Canada. Frequency follows the destination as well: 145 of these generators run at 60 Hz, which most of North America uses, and 40 run at 50 Hz, the standard in Europe and much of Asia and Africa. Equipment and grid must match the set's frequency.

Perkins engines are the most common, on 94 units, with Cummins, John Deere, Doosan, Scania, Volvo, Baudouin, Kubota, Yanmar and PSI / GM engines on the rest. To narrow the list, go to EPA generators or export generators, or tell us the destination country and the load.

Can't find the right configuration?

Tell us your required power, destination and application. Our team can help identify the right generator.

Compare generators

Values as published for each unit. Full specifications, documents and any market restriction are on each product page.